Test Code: MGX002
In the majority of Spinal Muscular Atrophy patients (>95%), the disease is caused by a homozygous loss of exon 7 of the SMN1 gene. This test allows the detection of deletions or duplication in the SMN1, SMN2 and exon 5 of the NAIP genes in genomic DNA isolated from human samples for the purpose of establishing or confirming a potential cause for and clinical diagnosis of Spinal Muscular Atrophy (SMA). This test can be additionally useful for carrier testing. Furthermore, the assay can be used for SMN2 (and NAIP) copy number determination in SMA patients to help prognosis and for treatment eligibility.
Multiplex Ligation-dependent Probe Amplification (MLPA)
Requirements: Collect 3 ml – 5 ml of whole blood in EDTA (purple top tube), minimum 1 ml for small infants.
Shipping: DO NOT FREEZE. Include a frozen ice pack in the shipping container. Place a paper towel or other thin material between the ice pack and the blood tube. At room temperature, a blood specimen is stable for up to 48 hours. If refrigerated, a blood specimen is stable for up to one week.
Requirements: Send 4 or more completely filled spots, each 10 mm in diameter. DBS cards should dry at room temperature for at least 3 hours after collection. DNA from DBS cards has inconsistent quantity and quality, which may result in delayed testing and/or the need for a second specimen.
Shipping: Send specimens at room temperature and after drying.
Requirements: Send in a screw cap tube at least 5 µg -10 µg of purified DNA at a concentration of at least 100 ng/uL, minimum 2 µg for limited specimens. Indicate concentration on tube label. For requests requiring more than one test, send an additional 5 µg DNA per test ordered when possible. DNA quality should be measured at A260/280 and be >1.8 for the sample to be acceptable for processing
Extracted DNA samples can only be accepted from CAP-accredited or equivalent facilities.
Shipping: Specimens may be shipped at room temperature. Label the tube with the composition of the solute and DNA concentration along with the patient’s name, date of birth, and/or ID number. DNA must be extracted using a column-based purification technique.
Requirements: Buccal Swab should be used according to manufacturer instructions.
Shipping: Specimens may be shipped at room temperature.